CMW
Cash Machine Welding & Fab · Anchorage AK
(907) 349-7649Call (907) 349-7649
Cash Machine Welding & Fab
Anchorage AK · 340 E 76th Ave
COMMERCIALRFQ-READY
REGION CODE · SECTOR 907
907
SECTORAK · South-CentralFAB SHOP340 E 76TH AVECONTACT(907) 349-7649

Commercial welding & fabrication for Anchorage.
Submittal-grade. RFQ-ready.

Structural steel · aluminum · stainless · pressure systems · mobile field welding. Built for property managers, GCs, facilities, and fleet operators across South-Central Alaska.

REQUEST RFQ PACKAGECALL (907) 349-7649
PROCESSES
MIG · TIG · STICK · FCAW
TICKETS
AWS · ASME · CWB
INSURANCE
GENERAL · AUTO · CARGO
RESPONSE
RFQ ≤ 48 HR
Commercial welding — arc strike in industrial shop
SHOP REFERENCE / FIG-01
Structural steel — single-pass MIG, low-hydrogen, qualified to AWS D1.1 procedure.
SPEC SHEET
SCROLL · SECTION 01/09
SECTION 02 / SPEC PLATE

Every weld references a spec.

Commercial buyers don't hire by photo gallery. They hire by procedure qualification. Scroll the plate — each weld pulls its own spec reference from the procedure book.

DRAWINGCMW-REF-0907-ASHEET01 OF 01SCALENTSREV02 · 05/2026
Welded structural steel detail — for spec annotation reference
01WELD PROCESS
GMAW · single-pass
REF · AWS D1.1 / 8.8
02FILLER METAL
ER70S-6 · 0.045"
REF · AWS A5.18
03JOINT GEOMETRY
BUTT · 60° GROOVE
REF · FIG. 3.5 / D1.1
04PWHT
NOT REQUIRED
REF · T-NUM / ≤ 1.5"
05INSPECTION
VT 100% · UT SAMPLE
REF · AWS QC1 CWI
DWG
CMW-REF-0907-A
PROC
GMAW-001
CALLOUT
01 / 05
SECTION 03 / SERVICES
SHEET 03 OF 09

Six commercial service lines.
Every weld procedure-qualified.

Each service line maps to a recognized code. We weld to your project's spec, not to a vendor catalog. Submittal packages issued on request.

Structural Steel — capability reference
S-01
CODE · AWS D1.1

Structural Steel

Beam, column, brace, deck. Built to drawing, qualified to procedure, inspected to spec.

  • Carbon steel · A36 / A572
  • Single-pass GMAW · FCAW
  • WPS-controlled · CWI signoff
Aluminum Fabrication — capability reference
S-02
CODE · AWS D1.2

Aluminum Fabrication

Marine rails, fleet bodies, plate work. GTAW-controlled, low distortion, accept-or-reject criteria on the invoice.

  • 5052 · 6061 · 6063 alloys
  • GTAW · pulsed MIG
  • Heat-input controlled
Stainless / Sanitary — capability reference
S-03
CODE · AWS D18.1

Stainless / Sanitary

Food-grade, processing skids, water-system piping. Orbital and manual GTAW with purge control.

  • 304 · 316L · duplex
  • Orbital tube · open-root
  • Boroscope · O₂ purge logs
Pressure Systems — capability reference
S-04
CODE · ASME IX

Pressure Systems

Code-qualified welds on pressure piping and small vessels. PQR-traceable, NDE-ready.

  • B31.1 · B31.3 piping
  • GTAW root · SMAW fill
  • RT · UT · MT capable
Heavy Equipment Repair — capability reference
S-05
CODE · FIELD · SHOP

Heavy Equipment Repair

Bucket cracks, frame fractures, attachment fab. Mobile rig or in-shop, fleet-operator scheduling.

  • Hardox · AR400 · AR500
  • Hardfacing · build-up
  • 24-hr turnaround target
Mobile Field Welding — capability reference
S-06
CODE · ON-SITE

Mobile Field Welding

Rigged trucks, on-site pipe and structural. Engine-driven units, hot-work permit ready.

  • Permit-ready crews
  • Engine-driven welders
  • Pipeline · rig · marine
SECTION 04 / CAPABILITY
SHEET 04 OF 09

Capability catalog.

What we fabricate, photographed by category. Project-specific reference lists and welder qualification records furnished to short-listed bidders on RFQ.

Structural · Carbon Steel — Beam splice · brace · column
C-01AWS D1.1
Structural · Carbon Steel
Beam splice · brace · column
FIG · C-01
Aluminum Plate — GTAW · 6061-T6 · fillet & butt
C-02AWS D1.2
Aluminum Plate
GTAW · 6061-T6 · fillet & butt
FIG · C-02
Stainless Tube — Orbital GTAW · 316L · purge-logged
C-03AWS D18.1
Stainless Tube
Orbital GTAW · 316L · purge-logged
FIG · C-03
Pressure Piping — Root · hot · fill · cap
C-04ASME B31.3
Pressure Piping
Root · hot · fill · cap
FIG · C-04
Heavy Equipment Repair — Bucket crack · frame · attachment
C-05FIELD
Heavy Equipment Repair
Bucket crack · frame · attachment
FIG · C-05
Mobile Field Service — Engine-drive · hot-work permitted
C-06ON-SITE
Mobile Field Service
Engine-drive · hot-work permitted
FIG · C-06
Want a project-specific reference list? It's on the RFQ packet, along with welder continuity records, insurance certificates and our shop tour.
REQUEST RFQ PACKET
SECTION 05 / REFERENCE
SHEET 05 OF 09

We don't market testimonials.
We furnish references.

Commercial buyers don't buy on stars — they buy on procedure qualification, welder continuity, and a verifiable reference list. Here's how that pull works on every Cash Machine RFQ.

PROCESS · RFQ TRACK
5 standard pulls. Issued in order. No invented endorsements.

STEP COUNT
05 / 05
REF-01

Project description

Share drawings, project scope, and the spec or code you build to (e.g. AWS D1.1 structural). We confirm fit before quoting.

REF-02

WPS / PQR pull

We provide the welding procedure and supporting PQRs for review by your engineer or third-party inspector.

REF-03

Welder qualification

Current welder continuity records and certification scope furnished on RFQ — no surprise non-qualified personnel on your job.

REF-04

Reference list

Project-specific references — same code, same scale, same buyer type. Furnished on shortlist, not in a public marketing list.

REF-05

Insurance + bonding

Cert of insurance issued with named additional insured, waiver of subrogation, and bonding capacity confirmed prior to award.

SECTION 06 / CREDENTIALS
SHEET 06 OF 09

The RFQ packet.

What every commercial buyer should be able to verify before award. We don't publish license numbers — those move to a verified buyer on contact, with full document copies.

REFCATEGORYSTATUS
CR-01
Business license
State of Alaska · active
ON FILE
CR-02
General liability
Cert of insurance · named additional insured
ON FILE
CR-03
Workers compensation
Alaska coverage · waiver of subrogation
ON FILE
CR-04
Commercial auto
Owned + hired · field rig coverage
ON FILE
CR-05
AWS / ASME procedures
WPS · PQR documentation
ON RFQ
CR-06
Welder qualifications
Continuity records · scope of approval
ON RFQ
CR-07
NDE & inspection
CWI / Level II partners — RT · UT · MT
ON CALL
CR-08
Bonding capacity
Disclosed under RFQ-NDA
ON RFQ
ON FILE = verifiable today. ON RFQ = furnished with RFQ submittal package. ON CALL = partner-supplied through contracted inspection houses.
SECTION 07 / SERVICE AREA
SHEET 07 OF 09

Where the rig goes.

Shop in Anchorage. Field welding across South-Central Alaska — Bowl, Valley, Kenai. Fly-out coverage for North Slope and remote industrial sites on contract.

Mobile rig response · hot-work permit ready · prevailing-wage capable

Z-01ANCHORAGEZ-02EAGLE RIVERZ-03MAT-SU VALLEYZ-04GIRDWOODZ-05KENAI PENINSULAZ-06NORTH SLOPEN50 MI
ZONE INDEX · 06
Z-01
AnchorageSHOP
Bowl · Hillside · Sand Lake
Z-02
Eagle River
JBER · Birchwood
Z-03
Mat-Su Valley
Wasilla · Palmer · Big Lake
Z-04
Girdwood
Turnagain Arm · Bird
Z-05
Kenai Peninsula
Soldotna · Kenai · Homer
Z-06
North Slope
Fly-out · field welding
SECTION 08 / RFQ
SHEET 08 OF 09

Open an RFQ.

Submit a project description. We respond within 48 hours with a fit confirmation, the WPS we'd weld to, and a target schedule. Phone faster — call (907) 349-7649.

RFQ INTAKE FORM · F-0907REV 02
Submittal package & references furnished after fit confirmation.